The effectiveness of continuous respiratory rate monitoring in predicting hypoxic and pyrexic events: a retrospective cohort study

Download (544.8 kB)
journal contribution
posted on 2022-09-05, 09:04 authored by Thomas A McCartan, Amy P. Worrall, Ruán Ó Conluain, Fátimah Alaya, Christopher Mulvey, Elaine MacHaleElaine MacHale, Vincent BrennanVincent Brennan, Lorna LombardLorna Lombard, Joanne Walsh, Myles Murray, Richard CostelloRichard Costello, Garrett Greene

Respiratory rate (RR) is routinely used to monitor patients with infectious, cardiac and respiratory diseases and is a component of early warning scores used to predict patient deterioration. However, it is often measured visually with considerable bias and inaccuracy.Objectives. Firstly, to compare distribution and accuracy of electronically measured RR (EMRR) and visually measured RR (VMRR). Secondly, to determine whether, and how far in advance, continuous electronic RR monitoring can predict oncoming hypoxic and pyrexic episodes in infectious respiratory disease.Approach.A retrospective cohort study analysing the difference between EMRR and VMRR was conducted using patient data from a large tertiary hospital. Cox proportional hazards models were used to determine whether continuous, EMRR measurements could predict oncoming hypoxic (SpO2 < 92%) and pyrexic (temperature >38 °C) episodes.Main results.Data were gathered from 34 COVID-19 patients, from which a total of 3445 observations of VMRR (independent of Hawthorne effect), peripheral oxygen saturation and temperature and 729 117 observations of EMRR were collected. VMRR had peaks in distribution at 18 and 20 breaths per minute. 70.9% of patients would have had a change of treatment during their admission based on the UK's National Early Warning System if EMRR was used in place of VMRR. An elevated EMRR was predictive of hypoxic (hazard ratio: 1.8 (1.05-3.07)) and pyrexic (hazard ratio: 9.7 (3.8-25)) episodes over the following 12 h.Significance.Continuous EMRR values are systematically different to VMRR values, and results suggest it is a better indicator of true RR as it has lower kurtosis, higher variance, a lack of peaks at expected values (18 and 20) and it measures a physiological component of breathing directly (abdominal movement). Results suggest EMRR is a strong marker of oncoming hypoxia and is highly predictive of oncoming pyrexic events in the following 12 h. In many diseases, this could provide an early window to escalate care prior to deterioration, potentially preventing morbidity and mortality. 

History

Comments

*The accepted manuscript is ‘the version of the article accepted for publication including all changes made as a result of the peer review process, and which may also include the addition to the article by IOP Publishing of a header, an article ID, a cover sheet and/or an ‘accepted manuscript’ watermark, but excluding any other editing, typesetting or other changes made by IOP Publishing and/or its licensors’.

Published Citation

McCartan TA, et al. The effectiveness of continuous respiratory rate monitoring in predicting hypoxic and pyrexic events: a retrospective cohort study. Physiol Meas. 2021;42(6).

Publication Date

29 June 2021

PubMed ID

34044376

Department/Unit

  • Beaumont Hospital
  • Medicine

Publisher

IOP Publishing

Version